Calculateur d’autonomie pour station électrique

Estimate how long a portable power station may run a device. Enter the battery capacity, average device load, efficiency and reserve. The result is a planning estimate, not a guaranteed runtime.

Estimated runtime

4.90 hours

Usable energy after efficiency
326.4Wh
Energy after reserve
293.8Wh
Formula
(Wh x efficiency x reserve factor) / watts

Actual runtime changes with load cycling, inverter behavior, battery age, temperature, cable losses and the output type used.

How the runtime estimate works

The basic calculation is battery capacity in Wh x efficiency x remaining reserve / average load in W. Capacity estimates available energy. Output wattage is a separate limit: the station must also support the device's running watts and startup demand.

Use average load for devices that cycle

Refrigerators, coolers, pumps and some CPAP configurations do not draw one fixed wattage continuously. A measured average over time gives a better estimate than using only the highest label value. Always check startup demand separately.

FlashFish capacity examples

ModelCapacityRated outputProduct page
A10197.68Wh120WView A101
P66A144.3Wh200WView P66A
E200151Wh200WView E200
T200153.6Wh200WView T200
A201172.8Wh200WView A201
E103179.2Wh300WView E103
T300PRO230Wh300WView T300PRO
P56288.6Wh330WView P56
E106B384Wh600WView E106B
T1200S768Wh1200WView T1200S
E112B1008Wh1200WView E112B
T20001536Wh2000WView T2000

Model coverage is based on verified technical data. Product availability may change; check the linked product page for current sales status.

Frequently asked questions

Why is the result lower than capacity divided by watts?

The calculator includes adjustable conversion efficiency and reserve. Real systems lose some energy through conversion, electronics, cables and standby operation.

Does a runtime result mean the device is compatible?

No. Check rated output, peak or startup demand, outlet type, voltage, frequency and device instructions separately.

Can I use this estimate for medical or life-critical equipment?

Do not use a general calculator as the only basis for life-critical planning. Follow the equipment manufacturer and qualified professional guidance and maintain an appropriate backup plan.

Does solar charging extend runtime?

It can, but solar input varies with weather, season, shade, panel angle and station input limits. Do not add rated panel watts as if they were constant all day.

Last reviewed: 16 September 2026.